TC Vaccum Tank 50L
Before filling the liquid nitrogen in the YDS series liquid nitrogen tank, we need to check whether the housing has depressions and whether the vacuum exhaust port is in good condition. If it is damaged, the degree of vacuum will be reduced. In severe cases, the intake air cannot be kept warm, so that the upper part of the tank will be frosted and the loss of liquid nitrogen will be large, thus losing the value of continued use.
[Company: Henan Tianchi Instrument Equipment Co., Ltd.]
TC Vaccum Tank 50L
Model
|
Volume(L)
|
Caliber(mm)
|
O.D(mm)
|
height(mm)
|
Net Weight(kg)
|
Static Storage(D)
|
Static Power Dissipation(kg/D)
|
Size (CM)
|
Gross
|
YDS-2-30
|
2.8
|
30
|
224
|
420
|
2.3
|
35
|
0.06
|
24*24*53
|
4.2
|
YDS-3-50
|
3.6
|
50
|
224
|
450
|
3.2
|
35
|
0.08
|
25*25*52
|
5.0
|
YDS-6-50
|
6.7
|
50
|
284
|
504
|
4.5
|
65
|
0.08
|
33*33*58
|
7.5
|
YDS-10-50
|
10.8
|
50
|
304
|
550
|
5.8
|
105
|
0.08
|
34*34*62
|
9.0
|
YDS-10-80
|
10.8
|
80
|
304
|
550
|
6.0
|
56
|
0.15
|
34*34*62
|
9.0
|
YDS-10-125
|
10.5
|
125
|
304
|
550
|
6.1
|
32
|
0.25
|
34*34*62
|
9.0
|
YDS-10-210
|
10.0
|
210
|
304
|
550
|
6.5
|
15
|
0.50
|
34*34*62
|
9.0
|
YDS-15-50
|
16.5
|
50
|
394
|
593
|
8.2
|
150
|
0.09
|
41*41*63
|
11.5
|
YDS-15-80
|
16.0
|
80
|
354
|
600
|
8.2
|
100
|
0.15
|
41*41*63
|
11.5
|
YDS-15-125
|
16.2
|
125
|
394
|
592
|
8.3
|
50
|
0.25
|
41*41*63
|
11.5
|
YDS-20-50
|
21.6
|
50
|
384
|
640
|
11.2
|
192
|
0.09
|
42*42*69
|
12.5
|
YDS-30-50
|
31.5
|
50
|
438
|
700
|
13.8
|
300
|
0.08
|
48*48*79
|
19.5
|
YDS-30-80
|
31.5
|
80
|
438
|
700
|
14.0
|
163
|
0.15
|
48*48*79
|
19.5
|
YDS-30-125
|
31.5
|
125
|
438
|
700
|
14.5
|
98
|
0.25
|
48*48*79
|
19.5
|
YDS-30-210
|
31.5
|
210
|
438
|
700
|
15.6
|
49
|
0.50
|
48*48*79
|
19.5
|
YDS-30B
|
31.5
|
50
|
438
|
700
|
14.2
|
190
|
0.13
|
48*48*79
|
19.5
|
YDS-35
|
35.8
|
50
|
461
|
740
|
14.6
|
310
|
0.09
|
47*47*83
|
20.5
|
YDS-35-80
|
35.5
|
80
|
461
|
740
|
14.8
|
173
|
0.16
|
47*47*83
|
20.5
|
YDS-35-125
|
35.5
|
125
|
461
|
740
|
15.2
|
110
|
0.25
|
47*47*83
|
20.5
|
YDS-35B
|
35.8
|
50
|
461
|
740
|
15.1
|
214
|
0.13
|
47*47*83
|
20.5
|
YDS-50B
|
51.0
|
50
|
476
|
815
|
20.4
|
248
|
0.16
|
56*56*95
|
30
|
YDS-50B-80
|
50.5
|
80
|
476
|
815
|
20.6
|
159
|
0.25
|
56*56*95
|
30
|
YDS-50B-125
|
50
|
125
|
476
|
815
|
20.9
|
131
|
0.30
|
56*56*95
|
30
|
YDS-50B-210
|
50.5
|
210
|
476
|
815
|
22.3
|
78
|
0.50
|
56*56*95
|
30
|
YDS-60B-210
|
63
|
210
|
476
|
815
|
23
|
98
|
0.50
|
56*56*95
|
30
|
YDS-80B-210
|
83
|
210
|
480
|
900
|
28
|
129
|
0.50
|
61*61*103
|
55
|
YDS-100B-210
|
104.8
|
210
|
606
|
1001
|
32
|
163
|
0.50
|
61*61*103
|
58
|
Liquid nitrogen tanks are special storage containers for liquid nitrogen. With the increasing use of liquid nitrogen, the use of liquid nitrogen tanks is increasing.
Users of liquid nitrogen tanks do not understand the structure of the tank and can only judge whether the bottle is intact or not by some surface phenomena. For example, customers see this statement in many places: liquid nitrogen tank frost, because liquid nitrogen tank is destroyed, liquid nitrogen leaks.
TC Vaccum Tank 50L